Waldent Physics Forceps - Pack of 1

Rs. 4,500.00

Size: W-100-R 1/138

W-100-R 1/138
W-100-L 1/139
W-100-A 1/140
W-200 1/141
Add to Wishlist
Specifications
Care Instruction
Features
  • W-100-R 1/138 - Upper right posterior extraction forceps
  • W-100-L 1/139 -  Upper Left posterior extraction forceps
  • W-100-A 1/140 -  Upper anterior extraction forceps
  • W-200 1/141 - Lower universal extraction forceps

Atraumatic  Forceps work under the "First Class Lever Principle" 

One handle of the device is connected to a “bumper,” which acts as a fulcrum during the extraction.

The beak of the extractor is positioned most often on the lingual or palatal root of the tooth and into the gingival sulcus

The bumper is most often placed on the facial aspect of the dental alveolus, typically at the mucogingival junction

No squeezing pressure is applied to the handles or to the tooth. Instead, the handles (once in position) are rotated as one unit for a few degrees, and then the action is stopped for approximately 1 minute.

The torque force generated on the tooth, periodontal ligament, and bone is related to the length of the handle to the bumper (8 cm), divided by the distance from the bumper to the forceps beak (1 cm).

As a result, a force on the handle connected to the bumper will increase the force on the tooth, periodontal ligament, and bone by 8 times. No force is required to be placed on the beak, which is only on the lingual aspect of the tooth root. Therefore, the tooth does not split, crush or fracture

 

  • Predictable and efficient extraction process
  • Ergonomic design for ease of use
  • Minimal operator movement and strength required
  • Preserves the socket and bone with atraumatic extractions
  • Eliminates root tip fractures
  • Quieter procedure, reducing patient anxiety
  • Reduced post-operative swelling
SKU:
Availability : In Stock Pre order Out of stock
Tags: Product

Share On

Description

Waldent Physics Extraction Forceps : The Unique design these forceps allows light but constant pressure to be applied to the tooth which leads to chemical changes in PDL and subsequent release of Sharpey's Fibers.

The Physics Extraction Forceps are an innovative design that provides a simple mechanical advantage by employing first-class lever mechanics. Utilizing the patented "beak and bumper" technique, you can simply and predictably extract virtually any tooth in any condition, while preserving the buccal bone and socket. The beak of the these forceps is designed to apply controlled pressure parallel to the long axis of the root. The bumper acts as a simple fulcrum or pivot point. While traditional instruments grasp, squeeze and twist, the physics extraction Forceps employs a slow, steady force that releases the tooth from the alveolar bone.

By combining the biomechanical advantages of a first-class lever with the biochemical reaction that is occurring, extracting teeth has never been easier than with the these forceps. When the periodontal ligament is traumatized with forceps or elevators, hyaluronidase is released. Once this chemical breakdown of the periodontal ligament by hyaluronic acid is sufficient, the tooth is released from its attachment to the alveolus and can be removed.

This explains why the Physics Forceps with its steady unrelenting trauma to the periodontal ligament quantitatively creates a greater release of hyaluronidase in a shorter period of time than traditional forceps or elevator extractions because the trauma from those techniques is intermittent. This is what makes the these forceps more efficient, faster, and less traumatic to the alveolar bone.

 Preserving the Bone

By utilizing the Physics Forceps Technique (no squeezing, applying constant steady pressure with the wrist only and using the bumper as a pivot/fulcrum), it is uncommon to break the buccal bone or cortical plate. Think of the Physics Forceps as an elevator – all you want the instrument to do is move the tooth 1-3mm through constant steady pressure allowing the PDL to separate from the tooth. Once this chemical breakdown of the periodontal ligament by hyaluronic acid is sufficient, the tooth elevates coronally. Also, the bumper acts as a compressive force that is holding the bone in place. Even though you are not squeezing, it is supporting the bone.

Additional Information
Size

W-100-R 1/138, W-100-L 1/139, W-100-A 1/140, W-200 1/141

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)