Impact DSI Internal Hex Dental Implant 4.20mm

Rs. 2,770.00

4.20mm: (Length 6mm)

(Length 6mm)
(Length 8mm)
(Length 10mm)
(Length 11.5mm)
(Length 13mm)
(Length 16mm)
Add to Wishlist
Specifications
Care Instruction
Features
  • Diameter:4.20mm
  • Size: 6mm, 8mm,10mm, 11.5mm, 13mm, 16mm
  • Implant Type: Internal Hex Dental Implant
  • Material: Titanium alloy
  • Immediate Loading: Designed for immediate loading procedures
  • Condition: Sterilized

Patient Evaluation:

  • Before implantation, thoroughly assess the patient's dental and medical history.
  • Conduct a comprehensive oral examination, including X-rays and scans to determine the suitability for dental implantation.

Treatment Planning:

  • Develop a treatment plan that outlines the implantation procedure, including the location, size, and type of the implant to be used.

Pre-operative Preparations:

  • Prepare the patient by explaining the procedure, potential risks, and expected outcomes.
  • Ensure that the patient is in good oral health and address any pre-existing dental issues.

Anesthesia:

  • Administer local anesthesia to numb the surgical area, ensuring the patient's comfort during the procedure.

Surgical Procedure:

  • Create an incision in the gum tissue at the implant site.
  • Prepare the bone to receive the implant using appropriate drills and instruments.
  • Place the Impact DSI Internal Hex Dental Implant 4.20mm securely into the prepared site.
  • Suture the incision site as needed.

Healing Period:

  • Allow time for the implant to integrate with the bone, a process known as osseointegration. This may take several months.

Prosthetic Attachment:

  • Once osseointegration is complete, expose the implant by making a small incision.
  • Attach an abutment to the implant, which serves as a connector for the final restoration (crown, bridge, or denture).

Final Restoration:

  • Create and place the final dental prosthesis (crown, bridge, or denture) onto the abutment.
  • Ensure proper alignment and aesthetics.

Post-operative Care:

  • Provide the patient with detailed instructions for post-operative care, including oral hygiene, diet, and any medications.
  • Schedule follow-up appointments to monitor healing and implant function.

Ongoing Maintenance:

  • Instruct the patient on the importance of regular check-ups and maintenance to ensure the longevity and success of the implant.
  • Compatibility: Compatible with various Israeli connections, including Adin, Alpha Bio, Noris, etc.
  • Connection Type: Internal hexagon connection for stability and compatibility.
  • Optimal Placement: Micro rings (5×0.2mm) for better placement in cortical and crystal bone, reducing further bone loss.
  • Design Feature: Platform switching design for enhanced aesthetics and soft tissue support.
  • Surface Treatment: RBM surface treatment to increase the success rate of the implant through improved osseointegration.
  • Body Design: Mild conical body for easy insertion of the implant.
  • Apex Design: Domed apex to release pressure on the implant.
  • Thread Design: Dual thread of 2.42mm (2×1.1mm) with reverse cutting thread for directional stability.
  • Cutting Efficiency: Two spiral channels for easy cutting of bone during the insertion process.
  • Compatibility: Compatible with various Israeli connections, including Adin, Alpha Bio, Noris, etc.
  • Connection Type: Internal hexagon connection for stability and compatibility.
  • Optimal Placement: Micro rings (5×0.2mm) for better placement in cortical and crystal bone, reducing further bone loss.
  • Design Feature: Platform switching design for enhanced aesthetics and soft tissue support.
  • Surface Treatment: RBM surface treatment to increase the success rate of the implant through improved osseointegration.
  • Body Design: Mild conical body for easy insertion of the implant.
  • Apex Design: Domed apex to release pressure on the implant.
  • Thread Design: Dual thread of 2.42mm (2×1.1mm) with reverse cutting thread for directional stability.
  • Cutting Efficiency: Two spiral channels for easy cutting of bone during the insertion process.
SKU:
Availability : In Stock Pre order Out of stock
Categories: consumables Impact
Tags: Product

Share On

Description

The DSI Dental Implant System is designed to combine clever engineering, simplicity and flexibility: the one-piece implant system that features unique bending ability, and uniform platform-switching internal connection designs (hex and conical).

The Impact DSI Internal Hex Dental Implant 4.20mm is a dental implant designed to offer outstanding performance and immediate loading capabilities. This implant is a singular, cohesive unit that consists of a body housing the implant itself and a straight structure.

The implant's key feature is its uniform structure, making it ideal for immediate loading procedures. This coating helps prevent bacterial growth, minimizing the risk of infection and ensuring optimal oral health.

The implant's surface treatment follows the same high-quality standards maintained across all products within our implant series. This consistent approach ensures that the implant is not only effective but also compatible with a variety of dental applications.

Constructed from a titanium alloy, the Impact DSI Internal Hex Dental Implant offers a combination of exceptional properties that are essential for successful dental implantation. Titanium alloy is known for its low specific weight, meaning it's lightweight and easy to work with. Despite its lightweight nature, it boasts a high strength-to-weight ratio, providing the durability required to withstand the demands of dental implantation. Additionally, titanium alloy exhibits very high corrosion resistance, ensuring long-term stability within the oral environment. Furthermore, its excellent general biocompatibility minimizes the risk of adverse reactions or rejection by the patient's body.

Notably, the titanium alloy used for this implant is categorized as ELI, standing for "Extra Low Interstitials." This particular alloy composition contains reduced levels of oxygen, nitrogen, carbon, and iron. These reduced interstitial levels result in improved ductility and better fracture toughness for the material. In practical terms, this means that the implant can endure the mechanical stresses of everyday oral functions while also providing the resilience necessary to withstand potential complications.

Additional Information
4.20mm

(Length 6mm), (Length 8mm), (Length 10mm), (Length 11.5mm), (Length 13mm), (Length 16mm)

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)